<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Austwide Cranes &#38; Chains &#187; Success Stories</title>
	<atom:link href="https://www.austwidecranes.com.au/advice/success-stories/feed" rel="self" type="application/rss+xml" />
	<link>https://www.austwidecranes.com.au/advice</link>
	<description>News &#38; Advice related to Cranes &#38; Equipment</description>
	<lastBuildDate>Thu, 18 Sep 2014 02:10:30 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=3.7.35</generator>
	<item>
		<title>Inspection Example</title>
		<link>https://www.austwidecranes.com.au/advice/inspection-example</link>
		<comments>https://www.austwidecranes.com.au/advice/inspection-example#comments</comments>
		<pubDate>Wed, 08 Jan 2014 23:15:18 +0000</pubDate>
		<dc:creator><![CDATA[Austwide]]></dc:creator>
				<category><![CDATA[Success Stories]]></category>

		<guid isPermaLink="false">http://www.austwidecranes.com.au/advice/?p=27</guid>
		<description><![CDATA[<p>Crane 1 Demag Girder SWF Hoist 5 Tonne DOM: 1984 No cross travel isolation supply. No long travel isolation supply. Anchor point load pin worn. No earth on the busbar supply (Refer to clause 5.4.1.1 from AS 3000). No final upper limit on the hoist (Refer to clause 8.8.8.1 from AS 1418.1.) No load limiting [&#8230;]</p><p>The post <a rel="nofollow" href="https://www.austwidecranes.com.au/advice/inspection-example">Inspection Example</a> appeared first on <a rel="nofollow" href="https://www.austwidecranes.com.au/advice">Austwide Cranes &amp; Chains</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>Crane 1 Demag Girder SWF Hoist 5 Tonne DOM: 1984</p>
<ul>
<li>No cross travel isolation supply.</li>
<li>No long travel isolation supply.</li>
<li>Anchor point load pin worn.</li>
<li>No earth on the busbar supply (Refer to clause 5.4.1.1 from AS 3000).</li>
<li>No final upper limit on the hoist (Refer to clause 8.8.8.1 from AS 1418.1.)</li>
<li>No load limiting device (Refer to clause 8.8.8.1 from AS 1418.1).</li>
<li>Main hoist gearbox has a large oil leak (seal kit req)</li>
<li>Hoist panel has no drawings and wires everywhere (rewire req)</li>
<li>Long travel torque arm requires new rubbers (a lot of movement in motor)</li>
<li>No drop plates on end carriages.</li>